This functionality is only available for certain module packages. Info / Copyright

Adopting the Connection Colors/Numbers of Cable Connections as Bundle Connection Point Designations

By means of the Overwrite bundle connection points menu item you can overwrite the bundle connection point designations of cable connections with the connection colors or numbers of the cable. For very long bundles, which often lead over several pages via interruption points, this allows the connection designations to be read at the bundle entry and exit points of the cable. When searching for errors in the schematic, this makes it much easier to follow a bundled cable connection between the cable target and the cable source.

Preconditions:

  1. Select the cable definition line.
  2. Select the Project data > Cables > Overwrite bundle connection points menu items.

    The bundle connection point designations 1, 2, 3 and 4 at both ends of the bundle are replaced with the connection colors BK, BU, BN and GNYE of the cable.

See also