EPLAN Fluid: Generation of Interruption Points to DIN ISO 1219-2

If the fluid schematic consists of more than one page and if fluid symbols on different pages are connected with each other, the standard DIN ISO 1219-2 specifies that a reference has to be declared at the interruption points of the connections (lines). The reference declaration has to be the same on both sides, it has to contain a hyphen as the separator, and it must state the number of the page on which the connection (line) is continued. The type of schematic (pneumatic, hydraulic, etc.) with specification of the schematic path can optionally be added to the connection reference.

Such interruption points corresponding to the standard can be created automatically in EPLAN Fluid on fluid power schematic pages during the inserting and cutting of schematic objects. Prerequisite for this is that you have selected the FL_1219-2_tpl001 project template for the project and that you have activated the so-called Smart connect (menu items Options > Smart connect).

The following data are then displayed in a rectangular text box: