This functionality is only available for certain module packages. Info / Copyright

Data Transfer of EPLAN PPE Projects

EPLAN PPE projects from older EPLAN versions (Version 2.6 or older) are converted automatically into pre-planning projects during opening and the subsequent updating of the project databases. (In order for this to be possible, both the Microsoft operating system and the Microsoft Office applications (inter alia Microsoft Access) therefore have to be installed completely in the 64-bit version.)

In the process, segments are generated from the information contained in the PPE database. The old project is preserved under a modified name. If the EPLAN PPE project contains documents a message is displayed in which you can decide whether these documents are to be imported as graphical pages.

During this automatic data transfer the following PPE objects are converted into the corresponding segments or objects of pre-planning:

PPE object

Segment / Object

Higher-level function

- PI system

- Designation

Structure segment

- Designation

- Description

The structure identifiers are determined on the basis of the configuration in EPLAN PPE.

PCT loop

PCT loop

PCT loop function

PCT loop function

PCT loop element

- Device type

- Device group

Planning object

- Description

- Segment definition

Specification

Segment template

Hook-up

Assembly

Orders

- Omitted -

Containers

Containers

Property

User-defined property. Property groups are displayed as part (additional node) of the identifying property name.

External document

Document (stored at the segment)

Document

Graphics page. During the opening and conversion of EPLAN PPE projects you can decide whether the documents from EPLAN PPE projects are to be converted into graphical pages or are to be ignored.

Note:

After the data import of an EPLAN PPE project further predefined planning objects (such as "Sensor", "Actuator", "Pick-up", etc.) and segment templates are available in the segment template navigator. These segment templates are based on the specifications from EPLAN PPE. During conversion the specification number in PPE becomes the identifying name of the segment template.

See also