Check usage
The option of usage checking checks whether the currently displayed structure identifiers are actually used in the project and, if so, how often.
Precondition:
You have opened a project in which identifier blocks are used in the project structure, for instance "Higher-level function" and "Mounting location".
Since the values in the Usage column are not stored, there is always a "?" value in the column when structure identifier management is opened, until you call up the command (or call it up again).
Note:
During this check, graphical pages are also processed to which a structure identifier has been assigned, or on which objects with structure identifiers are located.
Check syntax
The structure identifiers used are subject to a suppressible test for legal characters.
Precondition:
You have opened a project in which identifier blocks are used in the project structure, for instance "Higher-level function" and "Mounting location".
- Options > Settings > Projects > "Project name" > Devices > DT syntax check
- In the DT syntax checkdialog, select the Enable check check box, if the syntax of device tags is to checked during entry.
- In the group boxes Identifier blocks, Device tags, and Count numbers, specify the scope of the test for the components of the DT.
- Click [OK].
- Select the menu items Project data > Structure identifier management.
- Edit the structure identifiers as usual.
- Click [Apply] or [OK].
If an illegal character is found, the DT syntax check dialog is opened with the corresponding identifier highlighted.
See also