Exports/imports PLC data using the specified converter.
Parameter | Description |
---|---|
TYPE |
Type of task to be performed by the action BUSDATAEXPORT: Bus data export. BUSDATAIMPORT: Bus data import. GENERATEPLCSCHEMATIC: Schematics generation. EXPORTADDRESSOVERVIEW: Address overview export. |
PROJECTNAME |
Project name with full path. |
LANGUAGE |
Language identifier This parameter is only effective with the following values of the TYPE parameter: BUSDATAEXPORT, BUSDATAIMPORT |
CONVERTERID |
Identification for busdata exporter. Values are: • PlcDcExchangerBeckhoffTC3AML = Beckhoff TwinCAT 3 (AR APC 1.1.0) • PlcDcExchangerBoschAML = Bosch Nexeed Automation (AR APC 1.0.0) • PlcDcExchangerLogiCals3AML = logi.cals logi.CAD 3 (AR APC 1.1.0) • PlcDcExchangerMitsubishiAML = Mitsubishi iQ Works (AR APC 1.0.0) • PlcDcExchangerMitsubishi110AML = Mitsubishi iQ Works (AR APC 1.1.0) • PlcDcExchangerPhoenixContactAML = Phoenix Contact PLCnext Engineer 2019 (AR APC 1.0.0) • PlcDcExchangerRockwellArchitectAML = Rockwell Automation Studio 5000 (AR APC 1.0.0) • PlcDcExchangerSiemensTIA15AML = Siemens SIMATIC STEP 7 TIA-Portal 15 (AR APC 1.0.0) • PlcDcExchangerSiemensTIA151AML = Siemens SIMATIC STEP 7 TIA Portal 15.1 (AR APC 1.0.0) • PlcDcExchangerSiemensTIA16AML = Siemens SIMATIC STEP 7 TIA Portal 16 (AR APC 1.1.0) • PlcDcExchangerSiemensTIA17AML = Siemens SIMATIC STEP 7 TIA Portal 17 (AR APC 1.2.0) • PlcDcExchangerSiemensTSTAML = Siemens TIA Selection Tool (AR APC 1.1.0) • PlcDcAMLExchangerGeneral = Eplan Electric P8 AML-format • PlcDcXMLExchangerABB = ABB Automation Builder • PlcDcXMLExchangerBandR = B and R Automation Studio • PlcDcXMLExchangerRexroth = Bosch Rexroth Indra Works • PlcDcXMLExchangerSchneider = Schneider Unity Pro XL • PlcDcXMLExchangerSiemens = Siemens SIMATIC STEP 7 5.6 • PlcDcXMLExchangerUniversal = Eplan Electric P8 PLC standard exchange format This parameter is only effective with the following values of the TYPE parameter:BUSDATAEXPORT, BUSDATAIMPORT |
CONFIGURATIONPROJECT |
The name of the PLC configuration data set to export. This parameter is only effective with the following values of the TYPE parameter:BUSDATAEXPORT, EXPORTADDRESSOVERVIEW |
DESTINATIONFILE |
Destination file for data export. This parameter is only effective with the following values of the TYPE parameter:BUSDATAEXPORT, EXPORTADDRESSOVERVIEW |
SOURCEFILE |
Source file for data import. This parameter is only effective with the following values of the TYPE parameter:BUSDATAIMPORT. |
OVERWRITE |
If the output file already exists, this parameter specifies whether it should be overwritten. Possible values: '0' - No (default), '1' - Yes. This parameter is only effective with the following values of the TYPE parameter:BUSDATAEXPORT. |
IMPORTMATCH |
Matching options for PLC data import. The import process tries to match imported objects with those existing in the project. Based on the option selected, the matching may be performed by internal object ids or by objects' identifying names. If an imported object is matched with an existing function, properties of the existing function will be updated whereas for unmatched imported objects, new functions will be created in the project. The options are: 0 = Match by internal object ids. 1 = Match by identifying names. Note: in this case, a comparison dialog may be displayed for the user to individually selecting some function to update. 2 = Don't match. Create new functions for all imported objects. This parameter is only effective with the following values of the TYPE parameter:BUSDATAIMPORT. |
CONFIGFILE |
A path to a configuration file for schematics generation. This parameter is only effective with the following values of the TYPE parameter:GENERATEPLCSCHEMATIC. |
SINGLELINEPAGES |
If set, single-line pages will be generated. Possible values: '0' - No (default), '1' - Yes. This parameter is only effective with the following values of the TYPE parameter:GENERATEPLCSCHEMATIC. |
MULTILINEPAGES |
If set, multi-line pages will be generated. Possible values: '0' - No (default), '1' - Yes. This parameter is only effective with the following values of the TYPE parameter:GENERATEPLCSCHEMATIC. |
OVERVIEWS |
If set, overview pages will be generated. Possible values: '0' - No (default), '1' - Yes. This parameter is only effective with the following values of the TYPE parameter:GENERATEPLCSCHEMATIC. |
RACKOVERVIEWS |
If set, rack overview pages will be generated. Possible values: '0' - No (default), '1' - Yes. This parameter is only effective with the following values of the TYPE parameter:GENERATEPLCSCHEMATIC. |
PLCSTATION |
The name of the PLC station name to export. This parameter is only effective with the following values of the TYPE parameter:EXPORTADDRESSOVERVIEW |
PLCCPU |
The name of the PLC CPU name to export. This parameter is only effective with the following values of the TYPE parameter:EXPORTADDRESSOVERVIEW |