This functionality is only available for certain module packages. Info / Copyright

Migration of Enclosure Parts

The Migrate part functionality is a conversion aid for Rittal TS8-based projects to migrate existing individual parts from the Rittal baying system TS8 to the Rittal baying system VX25.

Note:

Please read the EPLAN Disclaimer of Liability Declaration first before you use the Migrate part functionality.

The following conditions and limits apply:

Automatic migration

Depending on the selection in the layout space navigator, a project, the complete contents of a layout space or an individual enclosure is analyzed and migrated on the part level. The following parts can be automatically migrated:

Note:

A peculiarity applies for bases / top modules: The migration generates a completely closed base with covers.

Manual migration

Non automatically migratable part placements can be migrated manually, for example:

Required check and post-processing after the migration

After the migration an exact check of the results should be carried out. Perform the following updates and checks at the migrated enclosure:

Correction of the enclosure distance for line ups

Since a VX25 enclosure is 2 mm wider than a TS8 enclosure, an intersection of the migrated VX25 enclosures occurs after the migration of an enclosure line up. The check run P026011 reports this as a collision.

To correct the distance within the line up, select the menu item Edit > Correct enclosure distance.

See also