Cause
A connection definition point was placed on a drawn connection between saddle jumper connections of distributed terminals with different designations for activated jumper optimization.
Solution
Possibility 1
- Locate the connection definition point in the schematic using the Go to (graphic) function from the popup menu in the Message management dialog.
- Delete the connection definition point on the connection between the saddle jumper connection points of the distributed terminals.
- Refresh the connections and then start a new check run.
Possibility 2
Or deselect the Jumper optimization property:
- Select the Options > Settings > Projects > "Project name" > Devices > Terminals (distributed terminals) menu items and deactivate the Jumper optimization check box.
- Refresh the connections and then start a new check run.