...Bundle / Network ID =<x>, Bus master / bus coupler = <y>, To bus master / bus coupler ID = <z>, Bus system = <u>, Position / Bus ID = <v>, Data transfer rate = <w>, Subslot = <r>, DNS/PROFINET device name = <s>
Cause
Several causes are possible:
- PLC boxes with communication units are still contained in your project.
- Or you have imported an old project with PLC boxes that contain communication units.
- Or you have imported old macros that contain PLC boxes with communication units.
Solution
You may handle the data as you wish:
- Create, for example, a new bus port or use an existing bus port and there enter the data found that are displayed in the placeholders of the message.
- Subsequently remove the existing communication units at the PLC boxes by means of the functionality Project > Organize > Compress.
Note:
This module-specific message is generated by the importing of PLC data. Using a new check run (any desired scheme) it can be deleted from the message management dialog.