This functionality is only available for certain module packages. Info / Copyright

P004058: Accessory part '<x>' at function '<y>' is only available in the project

Cause

When importing an AML file it was determined in the project that an accessory part '<x>' exists at the function '<y>' that does not exist in the import file.

Solution

  1. Locate the function in the schematic using the Go to (graphic) functionality from the popup menu in the Message management dialog.
  2. Check whether the accessory part is still required.
  3. If not, delete it at the function.
  4. Subsequently carry out the PLC import again.

Note:

This module-specific message is generated by the importing of PLC data. Using a new check run (any desired scheme) it can be deleted from the message management dialog.