Cause
The value of the PLC type designation property or of the Device description: File name property is empty at a PLC box that is assigned to a configuration project. Or no value is stored at both properties.
This check run only checks PLC boxes at which a configuration project is entered.
Solution
- Locate the PLC box in the schematic using the Go to (graphic) functionality that is provided by the popup menu of the Message management dialog.
- Open the property dialog of the PLC box.
- Bring the first tab to the front.
- In the properties table fill the required information either into the value field of the PLC type designation property or into the value field of the Device description: File name property.
- Click [OK].
- Then start a new check run.
Note:
If the Integrated module property in the PLC structure data tab is activated, the PLC type designation and Device description: File name properties in the first tab may remain empty.