Cause
In the case of a PLC box that disposes of inputs and / or outputs the required value is missing at the Start address 1 of PLC card property and / or the Start address 2 of PLC card property.
Solution
- Locate the PLC box in the schematic using the Go to (graphic) functionality that is provided by the popup menu of the Message management dialog.
- Open the property dialog of the PLC box.
- Bring the first tab to the front.
- In the properties table fill in the value fields of the Start address 1 of PLC card and Start address 2 of PLC card properties in accordance with the following conditions:
If the PLC box only has inputs, the value of the start address at the Start address 1 of PLC card property has to be entered.
If the PLC box only has outputs, the value of the start address at the Start address 1 of PLC card or Start address 2 of PLC card property has to be entered.
If the PLC box has inputs and outputs, a value for the respective start address has to be entered at both properties. - Click [OK].
- Then start a new check run.