Cause
At an unplaced connection the specification of the function which is the source and / or target of the connection is missing.
Solution
Possibility 1
- Open the connections navigator via the menu items Project data > Connections > Navigator.
- To locate the faulty connection, click the message in the dialog of the message management and select the menu item Synchronize selection from the popup menu.
- The connection is marked in the connections navigator.
- Call up the property dialog of the connection. Then add the device tag of a function existing in the project in the properties list at the property Source and / or at the property Target.
- Click [OK].
- Then start a new check run.
Possibility 2
- Select the menu items Project > Organize > Compress to remove data that is no longer needed from your project.
- In the compression settings activate the check box Remove unplaced connection.
- Then start a new check run.