This functionality is only available for certain module packages. Info / Copyright

P005051: Connector with unconnected connection point

Cause

A connector with at least one unconnected connection point was found in the schematic. For the purposes of this message, a connector is an angle, T-node, jumper, double junction or diagonal connection.

Solution

  1. Locate the relevant connector in the schematic using the Go to (graphic) function from the popup menu in the Message management dialog.
  2. Connect the open connection point(s) of the connector with a component so as to form autoconnecting lines.
  3. Delete the connector if it is no longer required.