Cause
A substance was defined at a connection in the P&I diagram. However, there no piping definition (piping connection point or piping definition point) at the connection.
Solution
- Locate the connection in the P&I diagram using the Go to (graphic) function from the popup menu in the Message management dialog.
- Open the property dialog of the connection definition point.
- Copy the value entered in the properties table for the Substance property into the Clipboard and then delete the value.
- Place a piping connection point or a piping definition point on the connection.
- Paste the copied value in the Clipboard into the Substance field in the property dialog of the piping definition.
- Specify the piping name and define its state.
- Refresh the connections and then start a new check run.