This functionality is only available for certain module packages. Info / Copyright

P005090: The pipe class '<x>' property of the connection contradicts the piping definition

Cause

The P&I diagram contains a connection on which a piping definition (piping connection point or piping definition point) is placed. The connection and the piping definition have different values for the Pipe class property.

Solution

  1. Locate the connection definition point of the connection in the P&I diagram using the Go to (graphic) function from the popup menu in the Message management dialog.
  2. Jump to the piping definition by using the Go to 2nd coordinate functionality of the popup menu.
  3. Determine the value entered in the Pipe class field in the respective property dialog.
  4. Standardize the two values or delete the value at the connection definition point.
  5. Refresh the connections and then start a new check run.