Cause
In the P&I diagram a part number is entered at a connection that does not match the part number that belongs to the selected pipe class.
Solution
Possibility 1
- Open the segment template navigator and call up the property dialog of the pipe class that is specified in the placeholder <y> of the message.
- Bring the Parts tab of the pipe class to the front.
- In the left-hand table supplement the part number <x> that is output in the message text of the connection.
- Then start a new check run.
Possibility 2
- Locate the connection in the P&I diagram using the Go to (graphic) button that is provided in the popup menu of the Message management dialog.
- Launch the property dialog of the connection.
- On the first tab select a pipe class that contains the part number <x> which is output in the message text.
- Then start a new check run.