Cause
You have added an additional function to a protected main function or main terminal that you have placed as a part with defined function templates (device), or you have changed a property of a function of the part. The part does not make this additional function available or does not use the retrospective change to a property of the part.
Solution
Possibility 1
- Select a part with suitable function templates for the protected main function or main terminal.
- Then start a new check run.
Possibility 2
- In the schematic, delete the function that was added to the part retrospectively, or undo the change to the function for the part.
- Then start a new check run.
Possibility 3
Extend the function template settings for the selected part in the parts management. Proceed as follows:
- Select the menu items Utilities > Parts > Management.
- Select the function or terminal in the tree or the list in the Parts management dialog.
- Bring the Function templates tab to the front.
- Click (New) above the Device selection (function templates)table.
A new row is added. - Click in the cell in the first column and then click [...].
- In the Function definitions dialog select the function you want, to extend the part.
- Click [OK], and apply the changed setting to parts management.
- Then place the device in the schematic again and start a new check run.