P007031: The part '<x>' entered at the function is not contained in the pipe class '<y>'

Cause

In the P&I diagram a part number is entered at a process engineering function that does not match the part number that belongs to the selected pipe class.

Solution

Possibility 1

  1. Open the segment template navigator and call up the property dialog of the pipe class that is specified in the placeholder <y> of the message.
  2. Bring the Parts tab of the pipe class to the front.
  3. In the left-hand table supplement the part number <x> that is output in the message text of the process engineering function.
  4. Then start a new check run.

Possibility 2

  1. Locate the process engineering function in the P&I diagram using the Go to (graphic) function from the popup menu in the Message management dialog.
  2. Launch the property dialog of the function.
  3. On the first tab select a pipe class that contains the part number <x> which is output in the message text.
  4. Then start a new check run.