This functionality is only available for certain module packages. Info / Copyright

P013048: A field named '<x>' does not exist and is therefore ignored

Cause

An invalid field name was found when importing the bill of materials. A field name in the import file may have been changed manually, and a typographical error has occurred. The result is that, after the import, the data in question is ignored and not displayed in the project as a property of the device.

Solution

Open the import file with a text or XML editor, and find the character string specified in the message management dialog under message "013048".

Compare the character string with the field name specified in the Help under Bills of Materials: Export File Fields. If you find the incorrect field names, correct them. Save the file, then import the bill of materials again.

Note:

Using a new check run (any desired scheme) this module-specific message can be deleted from the message management dialog.