This functionality is only available for certain module packages. Info / Copyright

P026014: Mounting clearances are not observed

Cause

When placing or moving a part on the mounting surface or mounting rail, the mounting clearance from the adjacent part was not observed.

The mounting clearances for a part can be specified in the Parts management, Mounting data tab. Use the Mounting clearance width, Mounting clearance height and Mounting clearance depth fields.

Solution

  1. From the Message management dialog, double click on the message to locate the part in the layout space in question.
  2. Move the part on the mounting surface or mounting rail, then start a new check run.