This functionality is only available for certain module packages. Info / Copyright

P026043: No routing track between source and target found. <x>

Causes

The routing path network between the source and target of a connection is incomplete.

Possible causes are:

Solutions

  1. Locate the source of the connection to be routed in the layout space using the Go to (graphic) functionality from the popup menu in the Message management dialog. You may also jump to the target of the connection to be routed in the layout space using the Go to 2nd coordinate functionality from the popup menu.
  2. Follow the routing path network in the layout space from the source or from the target.
  3. Add to the routing path network the missing routing path network object, such as the missing routing path.

    Or close the existing gaps between the routing path network objects by connecting them correctly graphically.

    Or checked the used connection filter and deactivate it if necessary.
  4. Start a check run (any check run scheme set) to delete the module-specific message from the dialog of the message management.
  5. Route the connections again.