Cause
No connection point pattern has been defined at the part placement in the layout space.
Solution
Store a connection point pattern on the part placement.
Possibility 1
- Locate the part placement in the layout space using the Go to (graphic) function from the popup menu in the Message management dialog.
- Open the Properties <...> dialog of the part placement.
- Bring the Part tab to the front, remember the part number assigned there, and close the property dialog.
- Select the Utilities > Parts > Management menu items, and navigate in the tree view of the Parts management dialog to the part that you have remembered.
- Bring the Technical data tab to the front, and next to the Connection point pattern field click [...].
- Select in the Select connection point pattern dialog that opens the name of the required connection point pattern and click [OK].
The name is transferred to the Connection point pattern field of the Technical data tab, and the connection point pattern is assigned to the part placement in the layout space. - Close parts management, save the modified data, and update the parts database.
- Then start a new check run.
Note:
If no connection point pattern has been stored in parts management, it will have to be created subsequently. Proceed as follows:
- Select in the tree view of parts management the Connection point pattern hierarchy level, and select the New popup menu item.
- Define the required connection point data on the tabs Connection point pattern, Connection points, and / or Attributes, enter a name for the connection point pattern, and click [Apply].
- Select in the parts tree the part, and assign to it the connection point pattern - as described above.
The assignment is then also implemented for the part placement in the layout space.
Possibility 2
- Open the Properties <...> dialog of the part placement.
- Bring to front the Connection point pattern tab.
- Activate the Local connection point pattern check box.
- Enter the required connection point designations in the table together with other connection point data.
- Close the Properties <...> dialog by clicking [OK].
- Then start a new check run.