Cause
When routing routing connections, a routing connection was found for which at least one of the following properties has not been defined:
- Part number
- Color / number
- Cross-section / diameter.
Solution
- Locate the routing connection in the layout space using the function Go to (graphic) from the popup menu in the Message management dialog.
- In the layout space, double-click the routing connection highlighted in color.
The Properties <...> dialog of the routing connection is opened. - In the dialog, bring to front the Part tab, and check whether a part number is entered in the table.
- If not, select the first row, and open the part selection with [...].
- In the tree structure navigate to the required part, and select it by clicking [OK].
- Switch to the Connection tab.
- Check whether the fields Color / number and / or Cross-section / diameter each contain a value.
- If not, add the missing value(s).
- Close the Properties <...> dialog by clicking [OK].
- Then start a new check run, and route the connections again.
Note:
Using a new check run (any desired scheme) this module-specific message can be deleted from the message management dialog.