Cause
Properties that are required for the air-conditioning calculation are missing at the enclosure.
The following properties have to be defined and have values assigned to them at the enclosure for air-conditioning calculation to be carried out:
- Power dissipation: Installation situation
- Power dissipation: Maximum external temperature
- Power dissipation: Minimum external temperature
- Power dissipation: Maximum internal temperature
- Power dissipation: Minimum internal temperature.
Solution
- Locate the enclosure in the layout space using the Go to (graphic) function from the popup menu in the Message management dialog.
- Call up the properties dialog of the enclosure and check on the first tab whether all the properties listed above are entered in the properties table and / or have values assigned to them.
- If not, add the properties and / or missing value(s).
- Then start a new check run.