Cause
The schematic contains a multi-line connection splicer that also has a corresponding counterpiece in the topology. However, the connection splicer was not found while routing the connections through the routing path network, because a routing point through which the connection splicer was already connected to the routing track was deleted.
Solution
- Locate the placed connection splicer with the "Topology" representation type using the Go to (graphic) function from the popup menu in the Message management dialog.
- Reroute the connection so that the connection passes a routing point to which the connection splicer is connected.
Or connect the connection splicer to a routing point that lies on the routing track. - Start a new check run after you have changed the device tags in order to delete the message.
- Route the connections through the routing path network again.
Note:
Using a new check run (any desired scheme) this module-specific message can be deleted from the message management dialog.