Cause
A PCT loop or PCT loop function created in the pre-planning navigator has not yet been placed in the "P&I diagram" representation type.
Solution
- Open the page of the "P&I diagram" type on which the PCT loop or the PCT loop function is to be placed.
- Open the pre-planning navigator (menu items Project data > Pre-planning > Navigator).
- Mark the message in the Message management dialog and select the popup menu item Synchronize selection.
The respective PCT loop or PCT loop function is marked in the pre-planning navigator. - Select the Place > P&I diagram popup menu item in the pre-planning navigator.
A symbol for a P&I diagram is shown at the cursor. - Click the left mouse button.
- Use the cursor to determine the size of the symbol that represents the PCT loop or the PCT loop function.
- Click the left mouse button again.
The PCT loop or the PCT loop function is placed on the page. - Then start a new check run.