Message number
Message text
P005001
Potential connection point or definition point without specification of potential
P005010
Connection without specification of potential
P005012
Several connection definition points on one connection
P005013
Targets have differing connection point types
P005014
Connection and connecting point have differing connection point types
P005015
Targets have differing potential types
P005016
Connection and connecting point have differing potential types
P005017
Target does not exist
P005018
Conflict between several connection definition points on a connection
P005019
Conflict between signal and potential
P005020
Conflict between identical potential definitions
P005021
Potential definition with incorrect potential
P005022
Connection definition point is located on more than one connection
P005023
Connection definition point is not located on a connection
P005024
Connection definition point without properties
P005025
Too many connections at a connection point
P005026
Connection point is not connected
P005027
Ring connection
P005028
Several potential definitions on one potential
P005031
A connection designation is added to the connection definition point (<y>) located on a section of the connection (<x>)
P005033
Designation process of format group no. <x>: First assigned connection designation '<y>', last assigned connection designation '<z>' within the format group
P005034
An identified connection definition point is located on a multiple connection
P005035
The connection definition point (<x>) on a multiple connection was re-arranged and re-formatted
P005036
The minimum number of digits for the format (<x>) was exceeded
P005037
Conflicting intrinsic safety of connection points
P005039
Representation types of targets differ
P005040
Bundle connection point is not in pairs
P005042
The value of the 'Color / Number' property is a color code or color name that is not contained in the project settings under 'Connection colors'
P005043
The cross-section / diameter is not contained in the project settings under 'Cross-sections / Diameters'!
P005044
Same connection designation on different potentials or pipings
P005045
Same connection designation on different signals or piping states
P005046
Incomplete net
P005047
Net definition point contains incomplete connections
P005048
Net contains connection symbols with the 'Specify targets' property
P005049
More than one net definition point on a net
P005050
Duplicate ID for net-based connections within a net (<x>)
P005051
Connector with unconnected connection point
P005052
Unconnected connection point at pin
P005053
Unconnected connection point at terminal
P005054
Different nets with identical net name (<x>)
P005055
Several signal definitions on one signal
P005056
Conflict between net and potential or signal
P005057
Net definition point with incorrect potential
P005058
Net definition point with incorrect signal
P005060
Connection point has a multi-line connection in both single-line and multi-line display
P005061
More than one multi-line connection definition at a single-line connection
P005062
Multi-line connection definition does not match source / target
P005063
Connection point is not contained in the multi-line connection definition
P005064
Invalid connection (source / target connection point does not exist)
P005065
Connections have conflicting data at the '<x>' property
P005066
Connection (multi-line) does not have a counterpiece (3D mounting layout)
P005067
Connection (3D mounting layout) does not have a multi-line counterpiece
P005068
Connection (3D mounting layout) with connection point that is not defined in the connection point pattern
P005069
Same connection designation on different nets
P005070
Different connection designations in a potential
P005071
Different connection designations in a signal
P005072
Different connection designations in a net
P005073
Different connection point cross-section / diameter of targets
P005074
Different connection point cross-section / diameter of connection and connecting point
P005075
Differing substances within a piping
P005076
Differing property '<x>' within a piping
P005077
Piping connection or definition point without specification of the substance
P005078
Connection with specification of substance without piping definition
P005079
Differing states within a piping
P005080
Connection (topology) does not have a multi-line / single-line counterpiece
P005081
Unrealistic continuous connection at the connection splicer
P005082
Cable connection without color / number
P005083
Conduit connection without color / number
P005084
The substance '<x>' property of the connection contradicts the piping definition
P005085
Connection is marked for deletion
P005086
Different connection dimension '<x>' / '<y>'
P005087
Direct connection: Different connection dimension '<x>' / '<y>'
P005088
Individual connection with DT
P005089
Connection definition point lies on a bundle
P005090
The pipe class '<x>' property of the connection contradicts the piping definition
P005091
Connection and function have differing pipe classes
P005092
The part '<x>' entered at the connection is not contained in the pipe class '<y>'
P005093
The connection diameter '<x>' does not lie within the permissible range of the terminal part
See also