This functionality is only available for certain module packages. Info / Copyright

Check Run Messages: Pre-planning

Message number

Message text

P028001

Structure segment occurring multiple times

P028002

Planning object occurring multiple times

P028003

Structure identifier occurring multiple times in structure segments (<x> = Structure identifier)

P028004

The planning object has several parts with potential main functions

P028005

The value sets at the segment or at the segment template do not match the macro specified

P028006

The full DT of the function does not match the pre-planning

P028007

Differing parts or number / quantity of parts between main function and associated planning object

P028008

The planning object has a function template for which there is no function

P028009

Not all functions / representation types of the device reference the same planning object

P028010

The data of the PLC connection point differ from the data of the PLC address in the pre-planning

P028011

PLC address at the planning object without placed PLC connection point

P028012

There is more than one graphical placement for the structure segment

P028013

There is more than one graphical placement for the planning object in the '<x>' representation type

P028014

The planning object has parts with templates and at least one additional template of its own

P028015

Segment with a '<x>' segment definition that is not to be used anymore

P028016

Segment is subordinated to a '<x>' segment definition that is not permitted

P028017

Identifying designation at PCT loops occurring multiple times

P028018

Difference between segment and segment template (property '<x>')

P028019

The macro at the planning object does not correspond to the placed macro

P028020

Macro at the planning object is not placed in the representation type 'multi-line'

P028021

Macro at the planning object is not placed in the representation type 'single-line'

P028022

Planning object is not placed in the representation type 'Pre-planning'

P028023

PCT loop or PCT loop function is not placed in representation type 'P&I diagram'

P028024

The pre-planning assigned to the object has been deleted

P028025

Macro at the planning object is placed several times in a representation type

P028026

The source and / or target segment is missing at the piping or cable planning object

P028027

Source or target '<x>' of the piping definition does not match the source or target segment '<y>' in the piping planning object

P028028

The substance '<x>' entered does not exist as a template in the project

P028029

The pipe class '<x>' entered does not exist as a template in the project

P028030

The pipe class entered at the piping definition point does not correspond to the pipe class '<x>' of the linked piping planning object

P028031

The part '<x>' entered at the segment is not contained in the pipe class '<y>'

See also