This functionality is only available for certain module packages. Info / Copyright

P004109: Difference between single-line and multi-line network structures

Cause

Within a project in which multi-line and single-line network structures are designed in parallel, there is a difference with regard to the device tag at one or more network / bus cable connection points.

Solution

  1. Locate the first network / bus cable connection point of the single-line or multi-line network by using the Go to (graphic) functionality from the popup menu in the Message management dialog.
  2. Track all the network / bus cable connection points that are connected to each other in both the single-line as well as the multi-line network and compare their device tags.
  3. If there are deviations, assign the same DT at the relevant network / bus cable connection points in the single-line and multi-line network structure.
  4. Then start a new check run.