Cause
Several interconnected bus ports are combined into a physical network. In the concrete case one or multiple bus ports connected to each other that are part of a physical network have different values assigned for the property Physical network: Name. The different values are output in the placeholders <x> and <y> of the message.
Solution
- Using the functionalities Go to (graphic) and Go to 2nd coordinate, which the popup menu of the Message management dialog offers, jump to the network / bus cable connection points of the physical network that are connected to each other.
- Call up the respective property dialog at the network / bus cable connection points and enter the same value in the Bus data tab in the Physical network: Name field. Or alternatively, enter the name of the physical network only at one of the network / bus cable connection points that are connected with each other and delete it at the other network / bus cable connection points.
- Then start a new check run.