By means of part selection, you assign one or more parts to a device. In the process the data listed below of the first part contained in the selection are assigned to the function / component.
General devices
Part |
Function |
||
---|---|---|---|
Property |
Property |
ID |
|
Coil: Voltage |
22218 |
Coil: Voltage |
20054 |
Switching capacity |
22072 |
Contact: Switching capacity |
20055 |
PLC type designation |
22105 |
PLC type designation |
20416 |
Device description: File name |
22037 |
Device description: File name |
20415 |
Object description |
22038 |
Object description |
20417 |
Version |
22104 |
Version |
20418 |
Address range |
22106 |
Address range |
20432 |
Address range 2 |
22261 |
Address range 2 |
20299 |
Bus coupler / head station |
22019 |
Bus coupler / head station |
20164 |
CPU |
22020 |
CPU |
20167 |
Power supply |
22052 |
Power supply |
20184 |
Bus distribution device |
22053 |
Bus distribution device |
20189 |
PLC station type / station type |
22269 |
Station type |
20409 |
Technical characteristics |
22017 |
Technical characteristics |
20027 |
Connection point cross-section |
22036 |
Connection point cross-section |
20057 |
Plugs: Number of pins |
22035 |
Plugs: Number of pins |
20056 |
In addition, the following values are transferred:
- All properties of the "main template". The main template is the first function template in the Function templates tab of the parts management whose function definition is set to "Main function".
- Part assignments set in the macro box (If a macro is entered at the part and part assignments are configured there).
- The value from the Technical characteristics field in the Technical data tab is only transferred during the part selection if no value is entered for this property at the "main template" or if there are no function templates.
Cables, conduits, lines
Part |
Function |
||
---|---|---|---|
Property |
ID |
Property |
ID |
Cable type / type designation |
22030 |
Cable / Conduit: Type |
20040 |
Connection: Cross-section / diameter |
22032 |
Cable / Conduit: Cross-section / diameter |
20043 |
Unit for connection cross-section / diameter |
22068 |
Cable / Conduit: Unit for cross-section / diameter |
20068 |
Number of connections |
22031 |
Cable / Conduit: Number of connections |
20042 |
Voltage |
22033 |
Cable: Voltage |
20044 |
Cable / Conduit: Designation in graphic |
22064 |
Cable / Conduit: Designation in graphic |
20067 |
Cable assignment diagram form |
22034 |
Cable assignment diagram form |
20092 |
Length (prefabricated) |
22055 |
Cable / Conduit: Length with unit |
20041 |
Connections
Part |
Function |
||
---|---|---|---|
Property |
ID |
Property |
ID |
Pipe class |
22224 |
Pipe class |
22224 |
Nominal pressure level |
22226 |
Nominal pressure level |
22226 |
Standard |
22227 |
Standard |
22227 |
Material |
22081 |
Material |
22081 |
Connection type |
22254 |
Connection: Type designation |
31048 |
Unit for connection cross-section / diameter |
22068 |
Unit for connection cross-section / diameter |
31059 |
See also