EPLAN Fluid: Generation of Interruption Points to ISO 1219-2

If the fluid power schematic consists of more than one page and if fluid symbols on different pages are connected with each other, the standard ISO 1219-2 specifies that a reference has to be declared at the interruption points of the connections (lines). The reference declaration has to be the same on both sides, it has to contain a hyphen as the separator, and it must state the number of the page on which the connection (line) is continued. The type of schematic (pneumatic, hydraulic, etc.) with specification of the schematic path can optionally be added to the connection reference.

Such interruption points corresponding to the standard can be created automatically in EPLAN Fluid on fluid power schematic pages during the inserting and cutting of schematic objects. Prerequisite is that you have selected the Fl_1219-2_bas001.zw9 basic project for the project and have activated Smart connect (Command path: Tab Edit > Command group Options > Smart connect).

The following data are then displayed in a rectangular text box:

  • Displayed DT of the interruption point
  • Separator
  • Identifier for the trade of the schematic page on which the counterpiece of the interruption point is placed
  • Page name (number) on which the counterpiece of the interruption point is placed
  • Separator
  • Designation or number of the line on the schematic page on which the counterpiece of the interruption point is placed
  • Separator
  • Number of the column on the schematic page on which the counterpiece of the interruption point is placed.