Cause
An invalid MasterSystemID was entered at a bus port that is assigned to the bus system "PROFIBUS" or an Ethernet-based bus system.
This check run only checks bus ports at which a configuration project is entered.
Solution
- Locate bus port in the schematic using the Go to (graphic) functionality that is provided by the popup menu of the Message management dialog.
- Open the property dialog of the bus port.
- Bring the Bus data tab to the front.
- If the "PROFIBUS" bus system is set, enter a value between 1 and 99 in the MasterSystemID property of the Properties of the network interface group box. If an Ethernet-based bus system is set, enter a value equal to or greater than 100 in the value field of this property.
- Click [OK].
- If required, start a new check run.
Note:
This check run is currently only relevant for SIEMENS control systems.