Cause
EPLAN has determined a faulty bus port. Which PLC card is affected and which properties of the bus port may have to be corrected is specified in the placeholder '<x>' of the message. The following information could be contained in the placeholder:
- The bus port of the PLC card with the device identification '<y>' may not have a plug designation
- The bus port of the PLC card with the device identification '<y>' has a faulty value in at least one of the properties: 'Bus system', 'Bus interface name', 'Plug designation'
Solution
Possibility 1
The first information in the placeholder is output:
- Locate bus port in the schematic using the Go to (graphic) functionality that is provided by the popup menu of the Message management dialog.
- Open the property dialog of the bus port.
- Bring the PLC connection point tab to the front.
- Check the value of the Plug designation property and correct it.
- Click [OK].
Possibility 2
The second information in the placeholder is output:
- Proceed as described under Possibility 1 with regard to Points 1 and 2.
- Bring the Bus data tab to the foreground when errors are reported with regard to the properties Bus system, Bus interface name and / or Plug designation and correct these.
- Click [OK].
If required, start a new check run.