Cause
No potential is defined at a connection.
Solution
Possibility 1
- Select the following commands: Tab Connections > Command group Connections > Navigator.
- To locate the faulty connection, click the message in the dialog of the message management and select the popup menu item Synchronize selection.
The connection is marked in the connections navigator. - Jump from the selected connection via the popup menu items Go to (graphic source) and / or Go to (graphic target) to the target functions in the schematic between which the graphical connection runs as an autoconnecting line.
- Place a potential definition point on this line.
- Specify a potential name in the property dialog.
- Click [OK].
Possibility 2:
For the case that you have created an unplaced connection, proceed as follows:
- To remove data from your project that is not required anymore, select the following commands: File > Extras > Command group Organize > Project > Command group Optimize > Compress project.
- In the compression settings activate the check box Remove unplaced connections.
If required, start a new check run.