P022025: The text angle is not equal to 0 or 90 degrees

Cause

A text was found in the schematic whose text angle is not equal to 0° or 90°.

Solution

  1. Locate the text in the schematic using the Go to (graphic) function from the popup menu in the Message management dialog.
  2. Call up the Properties <...> dialog of the text and bring the Format tab to the foreground.
  3. Assign the value 0,00° or 90,00° to the Angle property.
  4. Close the Properties <...> dialog by clicking [OK].
  5. If required, start a new check run.

Notes:

  • The check run is carried out for text on the following page types:
  • - Schematic multi-line
    - Schematic single-line
    - Fluid power schematic
    - Overview.

  • In the case of docked property texts, only the text of the main property is checked.
  • The check does not include texts of dimensions, texts within blocks, and texts within embedded reports.