Cause
When placing or moving a part on the mounting surface or mounting rail, the mounting clearance from the adjacent part was not observed.
The mounting clearances for a part can be specified in the Parts management dialog in the Properties tab. To this purpose properties such as Mounting clearance Width: Left, Mounting clearance Width: Right, etc. are available in the subordinate hierarchy level Mounting clearances of the hierarchy level Mounting data.
Solution
- From the Message management dialog, double click on the message to locate the part in the layout space in question.
- Move the part to the mounting surface or mounting rail.
- If required, start a new check run.