Notes:
- The check run does not consider 3D macros.
- This message is not output if unplaced functions are located in the macro.
Cause
In the parts database to be checked a part was found where a macro whose elements are not grouped is entered.
Solution
- In the message management dialog mark the line with the message and select the Properties popup menu item.
The Parts management dialog is opened, the respective part is already marked in it. - Bring the Properties tab to the front.
- In the property table click [...] in the Data hierarchy level in the value field of the Schematic macro property.
- From the selection dialog opening select a macro file that contains a schematic macro with grouped elements.
Or alternatively to this, delete the entered schematic macro in the value field of the property.
Or create a new macro with grouped elements, store it in the desired macro directory and select it again at the property. - Close the parts management, save the modified data, and carry out a parts synchronization.
- If required, start a new check run.