This functionality is only available for certain module packages. Info / Copyright

Dialog Number cables

In this dialog you specify the settings for numbering cable device tags and then you execute the numbering.

Note:

Ensure that nested DTs are excluded from numbering.

Overview of the main dialog elements:

Settings:

The scheme selected here specifies in which sequence cables are numbered, which properties are to be displayed in the cable DT and how they and formatted. Use [...] to open the Settings: Cable numbering dialog where you manage and edit the schemes.

Start value:

Enter the start value for the DT counter.

Increment:

Enter the value here to be used to increment the counter of the DT.

Keep existing cable DTs:

Select this check box if you would only like to renumber newly generated or copied cables. The DT of the already numbered cables is retained. The cables with "?" in the identifier will be numbered.

If the check box is deselected, all of the cable DTs are renumbered.

See also