Cause
You have connected at least one of the function connection points of the terminal with more components than specified.
Solution
Possibility 1
- Double-click the terminal in the schematic and select the Symbol / function data tab in the Properties <...> dialog.
- In the Function data group box click [Logic].
- Check which values are set for the function connection points of the terminal in the Number of targets line in the Connection point logic dialog.
- Increase your requirements in accordance with the set values for the function connection points.
Possibility 2
- Double-click the terminal in the schematic and select the Symbol / function data tab in the Properties <...> dialog.
- In the Function data group box click [Logic].
- Check which values are set for the function connection points of the terminal in the Number of targets line in the Connection point logic dialog.
- Accordingly, delete the excess placed components at the respective function connection points of the terminal in the schematic.
Update the connections.
If required, start a new check run.