Cause
Within a project in which multi-line and single-line network structures are designed in parallel, there is a difference with regard to the device tag at one or more network / bus cable connection points.
Solution
- Locate the first network / bus cable connection point of the single-line or multi-line network by using the Go to (graphic) functionality from the popup menu in the Message management dialog.
- Track all the network / bus cable connection points that are connected to each other in both the single-line as well as the multi-line network and compare their device tags.
- If there are deviations, assign the same DT at the relevant network / bus cable connection points in the single-line and multi-line network structure.
- Update the connections.