This functionality is only available for certain module packages. Info / Copyright

P005022: Connection definition point is located on more than one connection

Cause

The connection above and below the connection definition point branches at a T-node or a connection definition point is located on two crossing connections.

Solution

Possibility 1

Delete the target direction in accordance with the connection definition point before or after the T-node. Specify separate connection definition points for the branching connections.

Possibility 2

Move one of the connections from the intersection with the connection definition point.

Possibility 3

Move the connection definition point to one of the connections so that an intersection of both connections with the connection definition point is not possible anymore.



If required, start a new check run.