Cause
A connection symbol with at least one non-connected connection point was found in the schematic. Connection symbols in accordance of this message are the following:
- Angle
- T-node
- Jumper
- Double junction
- Diagonal connection
- Junction, angled connection (process engineering)
- Connection crossing with recess (process engineering)
- Gap for connection crossing
- Semicircle for connection crossing
- Piping interruption
A T-node in the schematic has a non-connected connection point (see circle in the following figure).
Solution
- Locate the relevant connection symbol in the schematic using the Go to (graphic) function from the popup menu in the Message management dialog.
- Connect the open connection point or connection points of the connection symbol with a component so that autoconnect lines are formed.
- Delete the connection symbol if it is not required anymore.
- If required, start a new check run.