Cause
The source or the target of a connection of which there are several representation types in the project is not available in the representation type. For example, the target of a routing connection of the type "3D mounting layout" that exists as a multi-line connection in the schematic has been deleted in the layout space.
Solution
Possibility 1
- Locate the connection in the schematic by using the Go to (graphic) functionality from the popup menu in the Message management dialog.
- Search the missing source or the missing target via the existing connection.
- Place the missing source or the missing target.
Possibility 2
- To remove data from your project that is not required anymore, select the following commands: File > Extras > Command group Organize > Project > Command group Optimize > Compress project.
- In the compression settings activate the check box Remove unplaced connections.
If required, start a new check run.