Cause
There exists in a layout space a connection of the "3D mounting layout" representation type whose connected source or whose connected target has a connection point designation that is not defined in the connection point pattern.
Solution
- Locate the connection of the "3D mounting layout" representation type in the layout space using the Go to (graphic) functionality from the popup menu in the Message management dialog.
- Follow the connection in the layout space both up to the connected source and the connected target.
- Check the connection point pattern at the source and target by calling up the Properties <...> dialog of part placement and bringing the Connection point pattern tab to the front.
- There, you delete the connection point designation that is not part of the connection point pattern, and close the Properties <...> dialog by clicking [OK].
- Then start a new check run.
Note:
The check run is also output if the connection point has been defined in the connection point pattern and all values in the columns for the X, Y, and Z position are set to "0".
In this case, enter a value other than "0" for at least one position of the connection point.