P005076: Differing property '<x>' within a piping

Cause

In the P&I diagram there are several piping definitions (piping connection points or piping definition points) that have the same piping name, the same substance and the same state, but have different values with regard to specific property <x>. The check run takes the following properties into account:

  • Connection designation
  • Connection: Cross-section / diameter
  • Connection color / number
  • Connection description
  • Connection: Length with unit
  • Type designation
  • Remark
  • Autoconnecting line: Line thickness
  • Autoconnecting line: Color
  • Autoconnecting line: Line type
  • Autoconnecting line: Pattern length
  • Autoconnecting line: Layer.

Solution

  1. Locate the piping definitions in the P&I diagram using the Go to (graphic) function from the popup menu in the Message management dialog.
  2. Open the properties dialog of each piping definition and enter the same value for the reported property <x>.