This functionality is only available for certain module packages. Info / Copyright

P007004: Duplicate connection point designation: <x>

Cause

Possibility 1

You have inserted a device with distributed functions in the schematic or created the device in the device navigator. This means at least two function are using the same connection point designation.

Possibility 2

You have placed a function in the schematic or created it in the device navigator and have assigned one or more identical connection point designations.

Solution

Regarding option 1

  1. Starting from the Message management dialog use the menu items Go to (graphic) or Go to (cross-referenced) to locate the functions occurring distributed in the schematic or device navigator.
  2. For every found function call up the Properties <...> dialog and compare the values respectively entered in the Connection point designations field.
  3. Assign a unique connection point designation to every function.

Note:

In the case of bus ports the bus interface name is used for identification in addition to the plug designation.

Regarding option 2

  1. Starting from the Message management dialog use the menu items Go to (graphic) or Go to (cross-referenced) to locate the functions in the schematic or device navigator.
  2. For the found function call up the Properties <...> dialog and note the entered values in the Connection point designations field.
  3. Assign a unique connection point designation to the function.


If required, start a new check run.

Note:

In the case of bus ports the Plug designation and the Bus interface name are used for identification in addition to the connection point designation. A check is carried out whether this combination (Connection point designation + Plug designation + Bus interface name) is identical. If at least one of these partial designations shows a difference, the message is not output.