Cause
Within the routing path network, a topology function has been found that is not a main function and whose function definition does not match the associated multi-line main function in the schematic.
Solution
- Locate the topology functions in your routing path network by using the Go to (graphic) functionality from the popup menu in the Message management dialog.
- Select the popup menu item Go to (2nd coordinate).
A jump is made to the multi-line counterpiece – the main function. - Call up the Properties <...> dialog of the main function, and switch to the Symbol / function data tab.
- Remember the entry in the Definition field under the Function data (logic) group box.
- Close the Properties <...> dialog of the main function using [Cancel].
- On the insertion point of the main function, open the popup menu, and select the Go to (counterpiece) menu item.
A jump is made to the topology function. - Call up the Properties <...> dialog of the topology function, and, here too, switch to the Symbol / function data tab.
- In the Function data (logic) group box in the Definition field, click [...], and set the same function definition at the topology function that is also set on the main function.
- Click [OK].
- If required, start a new check run.