Cause
You have generated a cable by means of the automatic cable selection. However, EPLAN did not find any cable parts in the Cable preselection dialog. The automatic selection is therefore terminated.
Solution
- Select the following commands: File > Settings > Projects > "Project name" > Devices > Cable (automatic).
- Click [...] next to the Automatic cable selection field.
- In the dialog Settings: Automatic cable selection click (New) in the toolbar of the Cable preselection table.
- In the tree view of the part selection that opens branch via the hierarchy levels Part > Electrical engineering > Component to the product group Cables and select a cable part matching the connections as far as possible.
- Confirm your entries.
- Regenerate the cable automatically again.
Note:
This module-specific message is output by the automatic cable selection. Using a new check run (any desired scheme) it can be deleted from the message management dialog.