Cause
A data transfer rate has been defined as a property and a value assigned to it for the bus slave of the specified bus port in the bus system.
Note that a data transfer rate may be defined only for the master of a bus system, but not for the bus slave! The master is defined via the Logical network: Bus port is master property.
Note:
This check run only checks bus ports at which the Configuration project (automatic, at bus ports) property is filled.
Solution
- Locate the bus slave in the schematic using the Go to (graphic) functionality that is provided by the popup menu of the Message management dialog.
- Call up the Properties <...> dialog again for the bus port of the bus slave and bring the Bus data tab to the foreground.
- Delete the Data transfer rate property from the table in the Properties of the network interface group box and close the Properties <...> dialog with [OK].
- Update the connections.
- If required, start a new check run.